This checklist is for information only. Not to be used as a plan submittal with the application. Identify all room uses, glazing, and all egress windows; a room with a closet is considered a bedroom. Exterior walls with a fire separation distance to lot line of less than 5 feet is required to be 1 hour fire-rated and tested in accordance with ASTM E 119 or UL 263 with fire exposures from both sides. Building projections with a fire separation distance to lot line of greater than or equal to 2 feet to 5 feet is required to be 1 hour fire-rated on the underside. Vapor barrier under all concrete floor slabs including garage with a minimum 12” overlap (minimum 6mil).  Crawlspaces must have the edges of the vapor barrier extend 6” up the stem wall and joints must be glued with an approved material. All plates in contact with concrete (interior and exterior, load bearing and non-load bearing) need to be pressure treated or decay resistance. Provide the thickness and height of basement walls and include size, spacing and grade of the horizontal and vertical reinforcement steel if required. Indicate if the crawl space is vented or unvented and if unvented provide the correct amount of exhaust ventilation and conditioned air supply is needed. Anchor bolts ?” X 10” in solid concrete and ?” X 18” into masonry should be located not more than 12” or less than seven bolt diameters from each end of the plate section and a maximum of 6’ on center.
Masonry piers in crawlspace need to be covered with termite shield or the use of pressure preservative treated wood.
Transitions between the basement and crawl or slab foundations shall be accordance to ACI 332 or shall be stepped where it is necessary to change the elevation of the footings. If floor system is an “I” joist system, provide a floor plan showing spacing, size, span and bearing points that indicate what is being used is adequate.  Specify the manufacture and series being used along with cut sheets showing uplift calculations prior to the framing inspection for review. Include a type and an elevation view of the garage wall bracing detail along with all measurements to scale. Provide a “complete load path” method that meets the requirements for the transfer of all loads from their point of origin through the load-resisting elements to the foundation.
All engineered wood floor joist assemblies constructed above basements, storage areas, habitable spaces, or other accessory areas must be provided with a finished ceiling of a minimum ?” drywall, and one (1) hour fire resistance rating.


If there is a living area over the portion of the garage, the garage ceiling and any walls , beams, posts, etc.
Townhouses must be protected by an automatic sprinkler system and a common 1-hour fire resistant-rated wall assembly tested in accordance with ASTM E119 or UL 263 or  be separated by fire walls built in accordance with Section 706 of the International Building Code and shall be classified as independent single-family dwellings.
Habitable rooms shall have a ceiling height of not less than 7’ measured to the lowest projection. Ice barrier is required on all roofs and shall be used in lieu of normal underlayment and extend from the lowest edges of all roof surfaces to a point at least 24 inches inside the exterior wall line of the building. Be in compliance with the 2012 International Energy Conservation Code.  Provide a wall section indicating the insulating method and the “R” values of the insulation. Exposed spray foam or insulated foam board insulation will be protected by an approved thermal barrier or meet the approved flame spread and smoke index values by an approved third party agency.
Minimum 3’ x 3’ landing at primary exit door is required.  Maximum 7 ?” drop allowed from top of threshold to top of landing. Window wells required for basement egress windows shall have horizontal dimensions that allow the door or window to be fully opened.  The horizontal dimensions of the well shall provide a minimum net clear opening of 9 square feet with a minimum horizontal projection and width of 36”. Window wells with a vertical depth greater than 44” must have a permanently affixed ladder or steps usable with the window in the fully open position.
Ladders or rungs shall have an inside width of at least 12”, shall project at least 3” from the wall, and rungs shall be spaced not more than 18” on center for the full height of the window well.  The ladder or steps shall be permitted to encroach a maximum of 6” into the required dimensions of the window well.
Window well covers shall be releasable or removable from the inside without the use of a key, tool, or special knowledge or force greater than that which is required for normal operation of the escape and rescue opening. Minimum 10” tread and maximum 7 ?” risers on any stairs.  Tread is measured from nosing to nosing. Minimum 6’8” finished headroom in stairways measured from a plane connecting the leading edges of tread nosing. Approved carbon monoxide alarm shall be installed outside of each separate sleeping area within 15 feet of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages.
Indicate on the foundation layout where the radon system will be located and install with a minimum 3-inch diameter ABS, PVC or equivalent gas-tight pipe that is embedded vertically into the sub-slab aggregate or other permeable material before the slab is cast.  Must use a “T” fitting within the sub-slab permeable material fitted with not less than 5 feet of perforated pipe extending from each horizontal opening of the T.


Studs, floor joists, ceiling joists, or rafters will not exceed the boring and notching requirements per the 2009 International Residential Code. Operable windows with sill heights 72”or more above grade and less than 24” above the interior floor surface need to be equipped with guards in accordance with ASTM F 2006 (Egress) or F 2090 (Non-Egress).
All pre-manufactured structures must be designed by a licensed architect or engineer.  The requirements shall meet the 90 mph wind speed and 20 psf roof load.
Revisions on plan resubmittals should be highlighted or clouded so that the changes are readily found during the plan review process.
The items listed above do not comprise an exhaustive list.  The presence of the information listed above (when applicable) will expedite plan review and issuance of permits.
Any plans and information pertaining to the grading and drainage, erosion control or sump pump discharge should be separate and attached to those application forms. Plan review time is subject to application and plans being complete and in compliance with all codes and ordinances. When a building permit application is submitted to Building Safety at the Champaign Fire Department, it is separated into its component parts and routed to whichever individual inspectors need to review a particular application. Any insulation sheathing on the exterior side of the wall must be an unfaced material with a perm rating less than one.
30” or more above floor or grade shall have approved guardrails.  Guards need to be a minimum 36” high with baluster spacing less than 4”. Seuss coloring pages and worksheets as fun family activities after you read the related book.
All departments welcome the chance to review particular portions of applications prior to their formal submission in order to make the permitting process proceed smoothly.
While most of these printable worksheets are listed by book, here are some printable activities that feature a variety of Seuss characters: Printable Seuss Bingo Game CardsDr.



Sign your childs rights over minors
Porta potties unsanitary
Diapers 4 life nj


Comments

  1. LOVELYBOY, 22.04.2014
    Training can take a month to several months which is of prime.
  2. 97, 22.04.2014
    And to stabilize himself with his feet to push throughout bowel movements practice employing the.