International Shipping - items may be subject to customs processing depending on the item's declared value. Your country's customs office can offer more details, or visit eBay's page on international trade. Estimated delivery dates - opens in a new window or tab include seller's handling time, origin ZIP Code, destination ZIP Code and time of acceptance and will depend on shipping service selected and receipt of cleared payment - opens in a new window or tab.
This item will be shipped through the Global Shipping Program and includes international tracking. Will usually ship within 1 business day of receiving cleared payment - opens in a new window or tab.
Returns will need an RA # (Return Authorization) number which must be on your return shipping label. By submitting your bid, you are committing to buy this item from the seller if you are the winning bidder. By clicking Confirm, you commit to buy this item from the seller if you are the winning bidder. By clicking Confirm, you are committing to buy this item from the seller if you are the winning bidder and have read and agree to the Global Shipping Program terms and conditions - opens in a new window or tab. All stations are pneumatically raised from the oil bath at the touch of a button allowing easy placement of the test specimens.
On loading, the test stations are lowered into position and the test can be started either from the handheld controller, or from an attached pc running Tinius Olsen’s HDV software. Air bearing guided loading rods on each test station is also featured to ensure smooth load application and precise measurement of displacement. Once the test is complete for all stations, the cooling cycle, using tap water as the coolant, starts automatically to allow more testing. Trending Materials StoriesKobe Steel to Build Aluminum Extrusion and Fabrication Plant in Kentucky, USAH.C. Spring manufacturers have given attention to ensure the quality of springs by testing them under different ranges of compression and tension forces. For the aforementioned problem, Tinius Olsen engineers found a solution that utilizes a supporting post attached to the lower compression platens to center the spring in order to adequately support the test piece when the compression load is applied. On the other hand, if the spring to be tested is especially long, then a support post that goes the entire length of the spring is needed. This information has been sourced, reviewed and adapted from materials provided by Tinius Olsen. The FH-5 series available from Tinius Olsen is a digital tester that features an excellent loadcell-based force feedback control loop to enable rapid, consistent and repeatable measurements and also to allow a large selection of test rates and test loads for nearly any type of test condition. Furthermore, the FH5 firmware removes overshoot by perceiving contact between the object's surface and indentor. With respect to the test areas, several options are available such as a motorized X-Y stage, a motorized X-Y-Z stage, or a manual X-Y stage. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. Contact the seller- opens in a new window or tab and request a shipping method to your location.
You have read and agree to the Global Shipping Program terms and conditions - opens in a new window or tab.


Import charges previously quoted are subject to change if you increase you maximum bid amount. They are utilized in a myriad of applications, including automotive engine, large stamping presses, vehicle suspensions, lawn mower, major appliances, pens, cell phones, medical devices, electronics and sensitive instrumentation devices, to name a few. These tests help a manufacturer to determine the performance of its springs in a specific job for which they have been made for. It is simple to apply this configuration to a standard S or T series testing machine from Tinius Olsen.
Tinius Olsen machines are designed for use in Research and Quality Control to measure material’s strength and performance.
This means the positioning of the indentor and the application and removal of test loads is completely automatic and absolute, and thus minimizes operator intrusion and subsequent errors. These options are set off by a CCD system with a video filar or a CCD system with video filar and autofocus.
The difficulty is that any two labs can easily come up with different results, making it difficult to determine whether a material meets a desired MFI spec. An extrusion plastometer, more commonly referred to as a melt indexer, is used to determine the MFI of virgin, compounded, and post-processed thermoplastics.The MFI test is used widely among the various segments of the plastics industry. If you reside in an EU member state besides UK, import VAT on this purchase is not recoverable. However, these tests face a common problem in the form of buckling of the spring under compression forces. The suitable solution is a machine configuration that has the load cell on the machine base and allows the support post to pass through the crosshead when it compresses the spring.
Additionally, the FH-5tester is equipped with a four position turret that can be configured by utilizing different objectives, stages, indentors or vision systems. As part of their materials-inspection procedures, some processors use the test to determine the amounts of recycled material that can be used in their product while still maintaining end-product specifications. Both offer a manual means (Procedure A or Method A) and automatic timed-flow measurement (Procedure B or Method B). Others may find that the alternative Melt Volume Flow Rate (MVR) procedure, offered by both standards, is more useful.No matter what the procedure selected, it is common for two organizations to test the same material and come up with two different test results, setting off a search to determine the reason for the difference. Has the machine been calibrated by a certified metrologist—checking temperature, physical dimensions, and distance- and time-measurement accuracy?
Are the operators properly trained and using the same testing technique?The chances of obtaining precise and accurate test results can be greatly increased by closely following proper testing procedures and requirements, by machine verification, and by periodic testing of control materials or a standard reference material (SRM).
ASTM D1238 offers a Troubleshooting Guide in the Appendix of the document and the following thoughts are based upon it. Some labs maintain their own supply of reference material, which they use to maintain in-house quality programs.
Participation is voluntary and the programs charge a fee, but they provide a benchmark to compare how your testing practices stand up against other participants. The range of factors that can contribute to questionable MFI test results is wide and deep. The verification procedure will check the dimensions of the machine, as well as the temperature-control and distance-measuring devices installed on the machine, for conformance to the relevant test standard. These should be replaced as necessary.Prior to running any tests, visually inspect all components of the testing machine.


The furnace of the instrument, which contains a heated metal cylinder with a defined bore, should be leveled using equipment typically supplied by the equipment manufacturer. Dimensional checks are to be made when the machine is cold.Cleaning the components of the test machine must be done after every test. No residue from prior tests should remain on the surfaces of the metal parts directly involved in the test. Solvents are usually not necessary nor recommended.The barrel finish should be mirror-like and free of rust, scratches, and imperfections.
Clean the barrel by repeated swabbing with a cotton cleaning patch using tools normally provided by the equipment manufacturer.
Some materials are a little more difficult to remove and may require the use of a brass brush.
The die should be visually inspected to make sure that the entrance of the bore is not chipped or rounded.
Periodically verify that the piston is straight and that the leading edge of the piston foot is sharp and free of burrs or damage that would cause it to rub against the wall of the barrel. Resin suppliers generally post their test conditions along with reported test values.Moisture content can be a large variable for some materials (ABS, PMMA, PET, and nylon, for instance).
Using a tool to pack material into the bore during the charging process is common practice, but it can result in variable test results for some materials if multiple machine operators are involved, because they commonly use different amounts of force to pack the material.
The piston foot is required to reach that point within 420 ± 30 sec after the material charging has been completed.
It is common to weigh the material prior to charging or to use a volume reference when charging the bore.Keeping enough material in the bore can be just as challenging for materials with higher flow rates. To meet the preheat and test start-time requirements, it may be necessary to unload the test load from the piston or stop its travel during the preheat period.
In some cases, the orifice needs to be plugged to stop the material from running out completely before the start of the test. Extra care must be used when dealing with high-flow materials to avoid burns.Extrudate cutting technique can be a factor in Procedure A tests.
A spatula or similar tool is used to cut material as it extrudes from the die at precise intervals.
However, it should be noted that the chances for error due to manual cutting increase with higher melt flow values. It is also important to note that the first cut (starting at 46 ± 2 mm) is considered to be the reportable test result.
This practice is acceptable as long as the specified distances are used.Procedure B requires the use of a melt-density value, which is the density of the material when it is in its molten state. These factors will change with additives and processing, so it is more accurate to measure the actual melt density of the specific resin being tested. You can combine a Procedure A and Procedure B test to give both weight and volume data, which allow calculation of melt density.If you are suspicious of the melt-flow data you are obtaining, you have plenty of options for checking and updating equipment, examining procedures, and comparing results with those obtained by others.



Ear nose throat yankton sd 32gb
Earring buy online india used
Hearos ear plugs xtreme protection review nz


Comments Tinius olsen load cells lima

  1. devo4ka
    Mass index (BMI), and diabetes.
  2. ALINDA
    Ring even though taking a shower pressure And are audible to other folks in addition to the patient. And.
  3. YERAZ
    Are homeopathic preparations advised to start drinking excessive amounts of coffee been a lot of anecdotal reports.