American woodworker cyclone review,toy box qld,woodworking plans door stand englisch,free floating glass shelves - .

I haven’t hooked the table saw up to it yet, although that is in the works, but I do have a clean up opening that I can use to sweep all the floor FOD into. I also have it hooked to the planer and it catches probably 95% or more of the chips and shavings and dust with no problem…. I have the Clearvue 5hp cyclone; I love it and I am completely satisfied with it, however, it is expensive. If that hypothesis is correct, opening some of your other blast gates for machines not in use should fix the problem, although probably at an increase in noise level. To answer your question better we need to know more about your intent, configuration and shop tools. In the earlier thread the group discussion was more along the lines of: do you need a canister? I like the unifence and have a power feeder that attaches to the fence so I’ve never been interested in changing it.
Grandpa…if you read my posts I was trying to understand the dimensions of the problem.
I was trying to get my wife to consider by a house in a Phoenix suburb; she has one relative in the area.
In this thread I’m trying to learn real world experiences with the different cyclones dust collectors. It is just hard to believe with as much intermet presence as they have that there are no reviews. Also they are the only company that talks about duct resistance, and a 15 .8 impeller is substantial. I looked at clear view, but with cost to add remote and shipping this was going to be over 25% more and I still have to buy the drum. Filter maintenance is an interesting issue, the subject of a thread I’m about to start. Pentz had a forum post that also commented on a configuration that would such the cyclone bin dry. The only thing that would do that is a leak in the dust bin, something I’ve checked with every source of smoke stick I could fine, there is none. Fred, Anytime you have to put the competitors product down to make your product look better, then you are having a problem competing. Cost does vary a bit, but not enough to be a show stopper or make one a clear favorite The ClearVue would be $1950, the Oneida $1680, the Grizzly $1650($1350 plus another $300 for aftermarket nano filters), and the PSI $1300. Fred, my hypothesis is that you have a well sealed ductwork…just not enough air entry creating too high a static pressure. If you would like further information send me a message and I would be happy to try and answer any questions that you may have.
Within 2 months I expect to have a dust collector, table saw with router table, and hoods around everything.
On the plus side, the trash can is extremely convenient—there is a really nice clamping system, and that and the wheels make it super easy to empty the can. In his review of the G0440 Cyclone Dust Collector, a test restriction, and used a manometer an ammeter.
Every drop is removable and I have a short piece of pipe with a cap over it to remove each piece from the system.
After providing them with samples of the dust in my filter, a layout of the system, and a considerable amount of other info, I never heard another word from them! If all the blast gates are closed it is trying to satisfy itself though the air openings in the one tool you are using.
If it works, a long term solution may be a new duct port near the cyclone with a blast gate and automotive air filter.
In our shops we have tools that may vary by a factor of 2x or 3x in air flow needs for dust collection and often size the DC to handle the largest with a buffer for error and expansion. After taking the filter off my 1.5 delta collector, I realized that I certainly was not turning the filter cleaner often enough. Commercial baghouse systems (the industry name for filter only systems) have continuous compressed air cleaning. As our filters get dirty the air pressure rises enough to force the fine sharp particles to cut and tear their way through the filter pores leaving us with wide open filters. In essence, the job of the cyclone is to keep almost all of the dust from reaching the filters, if having to clean the filters regularly is still part of the DC maintenance, then the cyclone is not efficient enough.
Most that you would vent would be too small to see and rest is just a little powder that is most like disbursed by the force of the discharge.
Hand power tools include a DeWalt circular saw, Bosch 470EB barrel jig saw, Bosch 1617 router with plunge, fixed, and when it arrives D-handle bases, an HF plunge router (not half bad), a couple of cordless drills, a couple of electric drills, one of the vibrating cutoff tools and then a bunch of metalworking stuff (note my picture), landscaping stuff, golf club building stuff, etc.. Wood fabrication may be an option; it certainly would look nicer but the added weight would require a stronger support. He found performance greater than the Grizzly published fan curve, although a similar knee in the curve at high static pressures that the 2006 American Woodworker article showed.


I have decided to go with the 3HP JDS unit as I believe it will more than suit my needs and since I am close enough to drive to Columbia SC where they ship from, I will save additional freight fees. Basically I run a Jet table saw off one port, one port works for my drill press, band saw ect.
It is going to be quite a challenge to use 6” but if you guys feel it best, even on these short runs, I will man up and start the project this weekend. But it replaced a shop built one (Wood magazine design) that was powered by a PSI 2.5HP SS DC. It may not be as fast and pretty or elegant as having blast gates or 5HP, but so far it works for me. That may be creating very high vacuum in the system, enough that it is vacuuming the cyclone and its bin. That should include a a couple of Oneida models, a couple of Penn State models, and the ClearVue. The first motor would not spin that fast (too much air through the ducts) and drew more power in an attempt to get to speed.
My guess is cleaning for a filter only system needs to be done after every use, and possibly several times per bin load. My hypothesis is that your ductwork is creating such high static pressure that the vacuum is emptying the dust bin. Makeup air solutions are possible, especially in the winter, but the cost exceeds the cost of the dust collection systems we are discussing. The American Woodworker article the dust in the Oneida and PSI as a trace and the Grizzly as a spoonful.
With all the savings, it will be almost $600 less than a clearview and I will not have to assemble. And the last port works as a modular station where I roll my router table, planer, and my 19” supermax sander. It might include a couple of Grizzly models if they had the right filter, which they are calling me back on next week. A cardboard box shell can help contain some of the visible saw dust, but the shopvac is pretty clueless on the fine stuff as it is ejected from a saw. They also used to sell the 2 HP model with a 2.5HP motor and a larger filter, which had some increase on air flow. Those brands have a long cone, the Laguna models have a tall cylinder with a fairly short cone. Since there were no air cleaners, vacuums or DCs turned on the air currents in the room were not influenced by any of those.
The size of the unit probably makes it a little less efficient, but as with everything in life there are trade offs. It lives in an insulated closet I built for it in a corner of the shop because it is loud!! An $1200 machine with shipping, Its graph shows over 900CFM at 8” of static pressure.
As the filter clogs airflow goes down affecting dust collection from the machine but the clogged filter will trap smaller particles as remaining spaces are smaller. Instead of a light shake or few taps we pull out 100+ PSI shop vacuum or our 120+ PSI air hose and really clean our filters.
ClearVue would probably site larger filter area, a better cyclone design, maybe a better impeller design, and a smoother path from the impeller to the filter. My current DC moves a lot of air, and to be honest everything is fine in terms of capturing the dust. But if you use a lot of fine dust producing tools (drum sander, for example) you really need that last 1% of separation.
In practice, the difference between the systems is probably too small to detect except in a controlled, back-to-back experiment and insignificant from a practical standpoint.
Based on what I’ve learned in the past week or so, I have a HEPA filter and Oneida Dust Deputy arriving later this week. THis means the particle count went from 20000 to 90000 just from the jigsaw creating dust being carried by the room air currents. The Oneida is built like a tank, but it skips the finer points of what Pentz proved to be good for separation. With units that are underpowered, letting more air in just adds to the problem, it puts more load on the impeller, drawing more power, etc.etc.
At 50 mins into the evaluation, I turned on the DC (G0440 2HP cyclone) and did some sanding with a spindle sander for about 20 minutes.



Easy kid wood projects ideas
Woodworking diy blog fashion
Table leg options
Coffee table folds out to dining table




Comments