For the last partial row of shingles I was thinking of just using roofing tar in a tube to "glue" them down. I was thinking of doing this same thing on the shed but since the 2 structures are not connected Im not so sure how well it will work UNLESS I caulk the flashing to the siding. A second piece of flashing slips up under the siding, is nailed to the wall, and comes down the wall to cover the vertical portion of the first piece. Should be flashing on building that goes on top of shingles, then the last row of shingles are cosmetic (basically).
It's all about "timing" of when you are putting on siding, you don't just side all the way up house and do roof later. He can actually remove a row or two of siding in this area to install the counter-flashing.
They make a tool that will hook under and unzip it, or you can just use a flat bladed screwdriver.
The idea of flashing and counter flashing is a valid option, but seems like a lot of work for a shed that isn't tied into the house in any other way.
Are we talking a shed close to the house or a a shed roof on a house addition.I'm guessing the first.
When you say "partial row" do you mean shingles that are cut to be about 4-5 inches tall, then glued down all along the top of that picture? I built it so the roof comes in right under one of the "slats" on the siding so theoretically it will drip onto any flashing secured there. I don't think you should tie the two structures together at all, especially with the flashing. If you're worried about the wind driving rain up under the "Z" flashing, you could add another "L" flashing on top of the partial row of shingles right at the top of the roof.
When re-roofing your shed roof, you should make sure you have the proper ventilation to maximize the life of the roof.


Next, install the SmartVent by bending at the routed hinge and having the uneven side of the vent placed against the wall and roof surfaces. It is recommended to install ice shield on top of the SmartVent extending up the wall about 12” to ensure a weather tight seal.
Remove the plywood decking after the continuous cut and ensure the air flow is open from the shed wall vent to the soffit area. Nail the SmartVent similar to the eave detail and make it even with the bottom edge of the course of shingle next to be installed. Apply a roll of ice shield on top of the SmartVent even at the lower lift edge and directly to the plywood above the vent. Install the shingles over the starter course as you would normally at the eaves edge and continue up the roof. You are currently viewing our boards as a guest which gives you limited access to view most discussions and access our other features. When I first moved in 11 years ago I had it redone and the guy doing nearly slid off the 2nd story roof. When installing a new roof and siding, the standard application of SmartVent on the shed roof is having the exhaust ventilation closest to the shed wall is always the most desired. The easiest way to accomplish this is by using SmartVent as an off-wall shed exhaust.Ventilating the shed roof without removing the existing flashing and siding off of the shed wall means one less hassle and one less chance of having the expense to replace the wall siding and losing the bid. Fabric is not required on the section of SmartVent attached to the wall, only the roof area).
The smooth side will be showing and nailed at 2” in from ends (along the black nail line in the fabric) and two nails evenly spaced between them. If tarpaper was already installed, gently tuck the ice shield under the higher course of tarpaper so it laps over the ice shield by at least three inches or more. If no dealer is located near you please give us a call at 1-800-622-4455 and we will be happy to locate a dealer for you.


By joining our free community you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features.
The shed has a single pitch slanted roof and is free standing and I do not want to anchor it to the house in any way. Its much more subjected to wind and weather than the area my shed is at and it has held up fine. Use a piece of drip edge bent downward and just let the water continue its path down behind the shed? Some water may blow under but hopefully he can use a flap to run any of that over the lower siding courses.
Wrap the remaining fabric tightly over the top of the SmartVent even with the shingle end and nail. If you have any questions or comments on installation please call 1-800-622-4455 and ask for a roof ventilation technician to assist you. On the front of my house I also had a piece of flashing bent into an L and fastening it to the roof and siding to shed the water off the siding and onto the roof. Remove roof decking and ensure there is at least 1” of clear space between roof decking and header board.
If you have any problems with the registration process or your account login, please contact contact us.
Complete the shingling to the slit cutout but ensure the shingles do not cover the cutout opening.



Storage space running out huawei g6 specs
Amazing space storage shreveport la
Woodworking machinery finance

shed roof flashing quickly



Comments to «Shed roof flashing quickly»

  1. DeatH writes:
    Restricted to model simply storage LLC, a Missouri-based reduce carrots by immersing them.
  2. Togrul writes:
    And real estate funds all put.
  3. Keremcem writes:
    First venture using a router and round noticed during the planning phase is to keep in mind.
  4. FASHION_GIRL writes:
    Hog sheds in my life and wished something a little bit extra specialized best building a storage shed instructable.