This article describes inspection methods and clues to detect roof venting deficiencies, insulation defects, and attic condensation problems in buildings. At INSULATION LOCATION & QUANTITY for ATTICS we discuss the relative benefit of adding insulation to a cathedral ceiling versus building walls in the same area. Some buildings, by their shape or design, simply don't make it easy to install continuous intake venting at the eaves or lower roof edge, or continuous outlet venting along a ridge.
For example, a house which has no roof overhang at all makes intake venting at the eaves difficult. Sketch (above left) is courtesy of Carson Dunlop Associates shows the two basic strategies for insulating cathedral ceilings and flat roofs. We call this a "hot roof" design because failing to vent the roof from below not only misses a chance to avoid ice dam leaks and condensation damage in cold climates. Watch out: Be sure to inspect the roof surface from outside for leaks and damage every year and to fix any damage quickly. The sketch above is provided ourtesy of Carson Dunlop Associates and shows the two basic strategies for ventilating cathedral ceilings or cathedral roofs.
Less insulation: Reduce under-roof insulation level to 3 A?a€? fiberglass (R-11) under the cathedral ceiling (not good energy savings) - not recommended but functional, just poor insulation value. Solid Foam: Install solid foam spray-in insulation under the roof a€“ a a€?hot roofa€? design. When re-roofing from the building exterior: if the roof decking and possibly roof framing have been extensively damaged by leaks it is usually necessary to repair the roof from outside the building.
The insulation used in those applications is tapered to provide positive roof drainage to roof drain points as well as to improve the building insulation system and cut energy costs. Tips for insulating a cathedral ceiling, take care to seal ceiling penetrations such as around light fixtures or ceiling-mounted hard-wired smoke detector. While fiberglass insulation is an excellent and effective product for insulating most building cavities, in areas where there is extra risk of trapping moisture (and thus rot or mold infections) such as crawl spaces and cathedral ceilings where roof venting may be absent or minimal, we prefer to use closed-cell foam insulation products or spray-in icynene foam insulation: these products can seal the cavity against drafts and they do not as readily pick up moisture nor do they readily form hidden mold reservoirs. In cases where there is no under-roof venting system (no soffit intake vents, no ridge vents), a "hot roof" design is followed: the roof cavity between rafters can be filled with insulation, followed by installation of a perfect vapor barrier, followed by finish surface of drywall or whatever else. While we prefer to avoid ice dam leaks by good building design and good under-roof ventilation, where conditions require stopping ice dam leaks on an existing structure, proper installation of heating cables may be the fastest and cheapest solution. Continue reading at HOT ROOF DESIGNS: UN-VENTED ROOF SOLUTIONS or select a topic from the More Reading links or topic ARTICLE INDEX shown below. Or see INSULATION LOCATION & QUANTITY for ATTICS to discuss the relative benefit of adding insulation to a cathedral ceiling versus building walls in the same area.
Question: What is causing drip marks from leaks out of cathedral ceiling in a Northern California House?
I'm not sure if I have answers to my specific issue solutions, so I'd like to give you some background and ask your opinion. A competent onsite inspection by an expert usually finds additional clues that would permit a more accurate, complete, and authoritative answer than we can give by email alone. I agree that it makes no sense to replace the roof covering before we have a clear diagnosis of the cause of leakage; Worse you could be wasting a lot of money re-roofing only to discover that "leaks" continue because the cause was improper venting, soaked insulation, air leaks, or that there is moldy drywall and wet insulation that need replacement in the ceiling.
Guess: the home has either one or more leaks into the roof cavity (cathedral ceiling) or condensation accumulating in that cavity. If heat is left on the water source could be an exterior leak, ice dam leaks, or interior air leaks carrying moisture into the roof cavity. If the water source in the roof cavity is from air and moisture leaks from the interior, the passage points into the roof are most often at penetrations such as around light fixtures.
Then I would go to the two most-suspect areas in the roof cavity and make a test cut sufficient to inspect the insulation for signs of wetting and mold, the cavity side fo the drywall for water and mold, and the roof sheathing for water, mold, and to confirm the air space. When we've done enough inspecting that we are confident of the cause of the drips you describe, only then does it make sense to start "repairing". I'm updating insulation on my cathedral ceiling on a 1966 bungalow which currently has no vapour barrier. You could add a layer of high-r foam insulation IF you are building a hot-roof unvented design.
If interior space permits I'd consider adding solid foam on the interior ceiling and new drywall over it to increase the total R.
I pose that the total project cost to R&R intact roof sheathing for this project is higher than insulating from the interior.
I'm unable to tackle this from the inside do to decorative wood paneling in the cathedral part of the roof that I don't want to disturb. Rigid board between rafters -which I've done -is a lot of cutting and fitting and sealing, and costly compared with spray-foaming the whole cavity. While we prefer the vapour barrier on the ceiling warm side, it's less critical than sealing around any ceiling penetrations on the inside (lights for example). We have a drop down ceiling in our office about 1200 sq feet with only one wll return for the ac.
You need an onsite inspection by a competent HVAC or other building professional to first understand how your system is designed.
Separately, if you are seeing sagging and moisture or condensation problems that is a potentially serious issue risking mold contamination and even ceiling collapse - conditions that need to be inspected as part of answering your question. I have a Big Beam house with all rooms, except bathrooms, with exposed ceilings of 2 x 6 Douglass Fir.
Certainly I would not do anything about your ceilings nor add insulation before doing some investigating. I'd go to the most-suspect point where leaks occurred and make a small opening, say 2x4" to look at the cavity side of the drywall, the wood framing, the existing insulation.
Questions & answers or comments about how to add or retrofit insulation to cathedral ceilings in older homes. ASHRAE resource on dew point and wall condensation - see the ASHRAE Fundamentals Handbook, available in many libraries. Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. America's Favorite Homes, mail-order catalogues as a guide to popular early 20th-century houses, Robert Schweitzer, Michael W.R. Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Brick Nogging, Historical Investigation and Contemporary Repair, Construction Specifier, April 2006.
Lighting, proper use of: proper aiming of a good flashlight can disclose hard to see but toxic light or white mold colonies on walls. Nogging: See this photo of exposed bricks on a building exterior on a building exterior in Canada.
Pergo AB, division of Perstorp AB, is a Swedish manufacturer or modern laminate flooring products. Rubblestone Wall Filler: See this Lartigue House using exterior-exposed rubblestone filler between vertical timbers of a post and beam-framed Canadian building. The Stairway Manufacturers' Association, (877) 500-5759, provides a pictorial guide to the stair and railing portion of the International Residential Code. The Illustrated Home illustrates construction details and building components, a reference for owners & inspectors.
DISCLAIMERThe purpose of this section is to provide design guidance for designing high performance assemblies. We will send your comments, along with a link to this page, to the appropriate project members. Revised by the Chairs of the Building Enclosure Councils with assistance from Richard Keleher, AIA, CSI, LEED AP and Kenneth Roko, AIA of The Facade Group, LLC. The foundation wall of a building may be a cast-in-place concrete retaining or basement wall or a structural wall complete with load-bearing pilasters. Readers are advised to obtain expert advice when designing systems which are below the water table or which are enclosing particularly vulnerable occupancies. This section provides specific description of materials and systems common in foundation walls and below grade building enclosure systems in general. Aggregate Drainage Layers—Aggregate drainage layers include graded pea-gravel aggregate or coarse sands.
Prefabricated Synthetic Drainage Layers—These products consist of a combination of plastic composite drainage cores with adhered geotextile fabrics. Design considerations include selecting an appropriate design to achieve the required flow rate.
Geotextile filter fabrics are also used for separating differing soil types in below grade enclosure applications. Dampproofing is intended to control vapor diffusion through the foundation, which can contribute to damp conditions on the interior.
Waterproofing membrane systems are available as either post-applied or pre-applied products for use in either positive-side, negative-side, or blind-side applications. Fluid-Applied Systems—These systems include urethanes, rubbers, plastics and modified asphalts. Sheet-Membrane Systems—Sheet membranes used in foundation wall applications include thermoplastics, vulcanized rubbers, and rubberized asphalts. Bentonite Clays—These systems include composite sodium bentonite systems with HDPE liners and geotextile fabrics, which are more common and more effective than the traditional systems. Cementitious Systems—These systems contain Portland cement and sand combined with an active waterproofing agent.
Waterproofing should be applied a minimum of 12" above finished grade, and then applied to a point 12" below the top surface of the interior slab on grade. If the exterior wall materials will not protect the waterproofing at grade, base flashings should be used to protect the waterproofing from ultraviolet (UV) radiation exposure.
In some situations, it may not be possible to apply waterproofing directly and entirely to the foundation walls, and it may be necessary to fasten a "lens" membrane to the foundation wall to catch runoff and redirect it away from the foundation. Protection Boards are used to shield waterproofing membranes from construction damage, damage from backfill materials in service, and ultraviolet radiation. In general, using prefabricated composite drainage board directly against certain waterproofing membranes as a protection layer is not recommended. Insulation materials used in below grade enclosure applications are primarily limited to rigid extruded polystyrene board due to the need for high compressive strength and moisture absorption resistance.
Waterstops should be utilized at construction joints in below grade walls, footings, slabs, and other elements where a waterproof system is required. Although not as common, pre-installed permeable grout injection waterstop may also be considered. Drainage pipes, typically 4" or 6" in diameter, used in below grade systems are primarily made of corrugated PVC or polyethylene and in some cases of porous concrete. All drain tile piping should be laid onto large, river-washed aggregate stones, which is laid onto a filter fabric, which should be wrapped around and over the drain tile to try to prevent fine soils from filling the drain tile. Structural Support Functions—The foundation wall system of the below grade building enclosure must be designed and constructed to support both vertical and lateral loadings. Vertical loads exist from the dead, live and lateral loads from the structure and the wall itself.
Lateral loads on foundation walls exist from the soil, surcharge and hydrostatic pressure loads.
In many cases the foundation wall is required to resist all of these loads directly with the wall designed as a cantilever retaining wall with a large base footing or as a basement wall spanning vertically between the foundation element and supported floors.
Special loadings such as blast loads are a design consideration in parking areas under and next to buildings.
Environmental Control Functions—The exterior environment that the foundation wall is subjected to includes environmental control loadings such as thermal, moisture, tree roots, insects, and soil gas.
Likely, the most predominant environmental control loading for foundation wall systems is moisture. Moisture that penetrates through the upper screen needs to be directed to the exit drain located at the base of the foundation wall. In many foundation wall situations with low water table elevations, the combination of the upper screen, the exterior drainage system, the near surface drainage system and the exit drain will control the majority of the water.
Even when it is necessary to apply a waterproofing membrane, it is recommended to also utilize a system approach including components of exterior drainage system, near surface drainage system and exit drain. Thermal considerations are of limited concern as one gets deeper down on the foundation wall as there is a constant, thermal design condition on the exterior. The higher soil temperatures on the exterior also create the need to provide at least a damproofing on the exterior of the foundation wall to resist the strong interior vapor drive.
Finish Functions—Two areas of finishes are of importance in relation to foundation walls. Distribution Functions—Foundation walls may contain distribution systems such as electrical and electronic runs.
Many areas around a building's perimeter at grade are subjected to high amounts of surface runoff from the high use of fenestration and impermeable wall facade materials, such as thin stone and EIFS.
Important design considerations include sloping the surface away from the structure, providing a suitable drainage system from the upper screen through the granular backfill, and a synthetic drainage layer that extends down to the perimeter drain. Drainage pipe at the perimeter of the foundation wall should be surrounded by a free draining granular material that is wrapped in filter fabric to prevent fines from filling in the porous spaces of the granular material. The designer must consider the overall water management system relative to site conditions and loadings to determine if dampproofing or waterproofing is required. For waterproof systems the first consideration is whether to use positive or negative side waterproofing.
Depending on site conditions and depth of the foundation wall, positive side waterproofing can either be installed from the exterior or directly to the lagging in a blind-side application prior to placing concrete. With fluid membrane systems, proper application in terms of coverage and thickness is critical to performance, and this should be monitored throughout the installation. In blind-side (positive-side, without access due to tight lot lines, under slabs on grade, or other reason) waterproofing assemblies, products may include sheet materials of thermofusible HDPE or PVC, bentonite, or other similar proprietary sheet products.
The best design intentions in selecting and detailing waterproofing systems can be undermined through damage from construction.
When designing the thermal, protection, and drainage elements to the exterior of below grade foundation walls, a slip plane should be introduced vertically within the assembly. Of critical importance in any building is the proper detailing and integration of the vertical building facade system and the below grade building system.
Façade terminations often produce the accumulation of moisture at or near the grade line of the building with the surrounding area. Condition appraisals and trouble shooting of below-grade structures reveals common sources of leakage that occur at penetrations.


Isolation, insulation and waterproofing of certain piping that undergoes large temperature changes are often underestimated for resulting movement. Common knowledge suggests that the seals serve as a back-up function and that avoiding moisture build-up is the principle objective for obtaining a leak free building at penetrations. Wall expansion joints should be designed to accommodate the anticipated structural movement. Construction joints have been effectively treated in most applications by a waterstop manufacturer's recommended details.
The details associated with this section of the BEDG on the WBDG were developed by committee and are intended solely as a means to illustrate general design and construction concepts only.
The details, graphics, and related information shown in the details are intended to illustrate basic design concepts and principles only and should be considered collectively with the appropriate narrative sections of the Whole Building design Guide (WBDG). NOTE: Photographs, figures, and drawings were provided by the original author unless otherwise noted. If you find the exact same plan featured on a competitor's web site at a lower price (advertised OR special promotion price), we will beat the competitor's price by 5% of the total, not just 5% of the difference!To take advantage of our guarantee, please call us at 800-482-0464 when you are ready to order.Our guarantee extends up to 4 weeks after your purchase, so you know you can buy now with confidence.
We offer a choice of three types of foundations, full basement, crawlspace, and slab foundations.
We will calculate a price and then email you a PayPal Payment Request prior to fulfillment. Typically adding an additional sub-panel to your home’s electrical system is required to accommodate additional circuits when either, your existing sub-panel is filled up, or you have several new circuits being installed in an area far away from where your existing sub-panel is located. Replacing your existing sub-panel with a larger one is another way to achieve more circuit breaker space to accommodate additional circuits. When your sub-panel has reached the age of 30; this is about the life expectancy of a circuit breaker. If the manufacturer of your panel is Federal Pacific, Sylvania or Zinsco, these manufacturers produced circuit breakers and panels that are considered to be fire hazards. If you have either intermittent power issues or flickering lights, and it has been determined that the buss, or one of the main lugs that the feeder wires connect to in your panel, is deteriorating than we recommend replacing your sub-panel.
A house with a pyramid roof shape or complex roof shapes makes outlet venting at a ridge difficult. In hot climates the roof temperature will be much higher on an un-vented roof, resulting in shorter shingle life. In buildings where there is no roof venting anyway, and where ventilation is difficult or impossible to achieve, an un-vented, well insulated "hot roof" can provide a high-R-value ceiling and may be the second-best alternative to preventing ice dam related leaks in cold climates. With 2x6 rafters this will give about an R-19 roof, higher if you use thicker solid foam insulation. Before replacing roof decking, consider re- decking the roof with insulated structural panels that include eaves to ridge ventilation in their design.
Adding ventilation under a solid-foam insulated pitched roof in order to dry and cool the building interior would, in turn, lose the benefit of the roof top insulation.
More moisture enters building cavities through these cuts in the ceiling (or wall) drywall than permeates through the drywall itself. In a cold climate and depending on the level of roof insulation, water entering the roof can freeze, accumulate as ice, and thus return to the interior as leaks and drips that continue for quite a while in thawing conditions.
If heat is off and the house interior is at freezing temperature (not my first choice for building preservation), the water source in the ceiling is more likely to be an exterior leak. The percentage of moisture that moves directly through solid drywall into a building cavity has been shown to be quite small.
In any event I would be cautious about leaving windows open in a home with heat off because of security risks, animal entry risks, blown snow and rain damage risks etc. The shingles need replacing so I will be tackling this from the outside by removing the roof sheathing.
Otherwise the foam layer atop the rafters and under the roof sheathing will have its R-value wasted since ventilating air would be moving between the underside of the foam and the upper side of insulation between the rafters. Should I look at going with only 2" of spray foam to provide the vapour barrier, add batting and then the rigid board insulation to cover the joists before sheeting? If the office ceiling space above the drop ceiling is being used as a return air plenum you don't want to subvert the design by adding addtional vent openings. Finally: consider (but defer) using an insulated chimney from the ceiling up through the roof. It would be a shame to simply blow insulation into a cavity only to find later that you have to remove the whole shebang to get rid of moldy drywall that nobody attended. It was a common construction method that employed masonry as infill between the vertical uprights of wood framing." -- quoting the web article review.
The text is intended as a reference guide to help building owners operate and maintain their home effectively. Your information will not be kept in our records or used for any other purpose than to send the message. The plastic composite "dimpled" drainage cores are available in various configurations and are typically constructed using polypropylene, polystyrene and polyethylene.
This separation of differing soil types maintains flow rates of soils used as drainage layers and minimizes settlement from finer materials filling in more coarse materials. Cementitious products are generally portland cement based and typically trowel-applied or brush-applied.
Positive-side waterproofing systems are post-applied to the surface of the element that is directly exposed to moisture, typically the exterior side of the foundation wall.
Fluid-applied membranes are applied in liquid form and cure to form one monolithic seamless membrane.
Bentonite clays act as waterproofing by swelling when exposed to moisture thus becoming impervious to water. These systems include metallic (metal oxide), crystalline, chemical additive, and acrylic modified systems. Typically, the waterproofing is wrapped over a masonry brick shelf, or up behind the finish exterior materials at grade so that it may be terminated and shingle lapped by the weather barrier. These flashings are usually stainless steel to resist corrosion in contact with grade soils and moisture.
It is recommended that a 60 mil PVC membrane or polyolefin membrane be used, set on a concave sand bed and fastened to the foundation wall with a stainless steel termination bar with standard waterproofing applied to the wall above that point. The most commonly used protection board is a semi-flexible sheet containing an asphalt core placed between asphalt impregnated glass fiber mats.
Although the composite board may have a polyethylene sheet on the membrane-side, this sheet is often cut, damaged, or missing. For optimum drainage and thermal performance, install a composite drainage board with integral filter fabric to the exterior of the insulation. These systems provide a secondary barrier to the passage of water across these construction joints. Typically constructed with flexible PVC, permeable grout injection tubes are installed in construction joints and are injected with grout only if leakage is observed. PVC and polyethylene pipes are available in smooth or corrugated configurations and are slotted on the bottom half of their cross-section to allow water infiltration. Regarding slope to drain, drain tile is intended to be installed with some slope to ensure that the water moves toward the sump collector.
Structural Support, Environmental Control, Finish, and Distribution as they relate to the below grade enclosure elements of foundation walls. Structural Support, Environmental Control, Finish and Distribution, are expanded below in general terms for foundation walls. The foundation wall may be an integral part of the load bearing design of the building carrying column and floor loads from above, either as distributed loads on the wall or point loads on pilasters integral to the wall system. Other cases may include an earth retention system, such as piling and timber lagging, facilitating construction and designed to resist the lateral loads leaving the foundation wall to resist primarily vertical loads.
While the first control of these abnormal load events are through security entry control systems and restricted access, structural design considerations may also be required in the design of the foundation wall system. The interior environment that the foundation wall is subjected to includes environmental control loadings such as thermal and moisture. This is accomplished through a drainage system at the exterior of the wall that is typically a free draining granular material. The key question that remains is whether to provide dampproofing or waterproofing to the surface of the foundation wall or not at all. The removal of the moisture in the most complete and expeditious manner will decrease the probability for intrusion of water.
In fact, in some situations, conditioned below grade spaces are subjected to a constant inward vapor drive during summer as the interior space is air conditioned, and in the winter the interior space is heated resulting in a lower vapor pressure than the exterior condition as the soil stays relatively constant in terms of vapor pressure. Proper treatment of this area is critical in terms not only of aesthetics but also durability.
Many waterproofing membranes need to be shielded from ultraviolet radiation to prevent deterioration and as such some type of exterior finish is required.
At times these systems are run internally in the interior surface finish system or in ceiling space. The first and most effective defense against this water is to slope the upper screen surface away from the building a minimum of 5% near the building edge.
If in doubt, it is clearly prudent to err on the conservative side and provide a waterproof system. Although negative side waterproofing is advantageous from the standpoint of repair ability, most foundation wall applications utilize positive side waterproofing, because the force of nature is on your side, pushing the waterproofing against the backup.
For application from the exterior, the next design decision is to use fluid applied or sheet products.
The key advantage to fluid systems is their monolithic nature and self-flashing abilities as the material is applied in liquid form. In all applications, protection of the membrane and proper lapping and sealing of joints is critical. For positive side applications, the installation of protection boards or insulation layers as quickly as possible after membrane installation is critical to prevent mechanical damage form subsequent layers and backfill and form ultraviolet radiation.
Location of the slip plane may vary depending on the design; however, it should be included in all assemblies. The drainage board should have the protection sheet on the backside of the core to promote better movement against the insulation.
The integration of the two systems requires careful consideration to insure that all moisture, air and thermal criteria for each system are satisfied at the transition interface.
A special flashing behind face stones of buildings or special flashing and treatment of the exterior slab edge where it is adjacent to ground features is required.
Common practice for wall terminations or door entries is to provide slope away from the building as previously indicated.
Penetrations are any openings in the wall or structural system that, if not properly waterproofed, provide an avenue of breech for moisture entry into the building. Where expansion and contraction of the services or pipes entering the building occurs, a sleeve through the wall that is discontinuous with the penetration piping is required.
Notre that leakage may occur at a penetration and flow behind the waterproofing if a lateral path exists. For many membrane types, a multiple layer detailing of the membrane, proper isolation and allowance for joint detailing is generally effective for construction joints. Appropriate use and application of the concepts illustrated in these details will vary based on performance considerations and environmental conditions unique to each project and, therefore, do not represent the final opinion or recommendation of the author of each section or the committee members responsible for the development of the WBDG.
The information contained therein is not intended for actual construction, and is subject to revision based on changes and or refinements in local, state, and national building codes, emerging building envelope technologies, and advancements in the research and understanding of building enclosure failure mechanisms. Often your existing sub-panel doesn’t have the physical breaker space needed to accommodate arc-fault circuit breakers. This gives the best air path, eaves to ridge, but costs more for the labor to nail furring and cut insulation into pieces to fit between rafters.A  a€“ works well, costs more.
Worse, once the insulation has become wet the cavity has lost insulation value so the problem is likely to be worse, especially if the source is condensation from inside. I do like eaving heat on to keep the home above freezing, say at 40 or 45F which can avoid building damage that comes from extreme temperature swings inside - conditions that are not anticipated by most modern construction; But as I suggest, let's wait on the cure until we understand the disease. From your articles you still recommend a vented design to keep the roof cool in the summer and prevent premature wear on the shingles. So, I have to use spray foam or rigid board(sealed around the edges) between the rafters vs the batting because of no vapour barrier correct? Readers should see INSULATION R-VALUES & PROPERTIES our own table of insulation properties that includes links to articles describing each insulation material in more detail.
The Manufactured Home Owners Association of America is a National Organization dedicated to the protection of the rights of all people living in Manufactured Housing in the United States. It is the intent to provide recommendations which go beyond the content of those standards, especially as it relates to integrating assemblies into a total building enclosure design.
Harvey, AIA, RWC, LEED AP of Applied Building Sciences, and Joshua Kelly of Simpson, Gumpertz and Heger. The foundation wall system may include an earth retention system of soldier piles and wood lagging or shotcreted rock requiring consideration of waterproofing applied to the earth retention system. The geotextile fabrics retain sand, soil, concrete, or grout allowing water to migrate into the free draining core. Geotextile fabrics are typically constructed using polypropylene, polyester, or nylon and are available in either woven or non-woven designs.
Dampproofing is always applied on the positive side, or wet side, of the structural element. Negative-side waterproofing systems are post-applied to the surface of the element opposite the surface exposed to moisture, typically the interior of the foundation wall.
For foundation wall applications, typical cold applied fluid applied systems are approximately 60 mils in thickness. If heat-welded seaming is employed and loose-hung membranes are tough and protected from damage by protection board, they may be effective waterproofing materials, but if a leak occurs, the leak will be difficult to locate and correct due to the loose application of the waterproofing layer in those cases. The latter two should not be used as waterproofing except for the most non-critical conditions.
When it is wrapped over masonry ledges, care must be taken to coordinate with masonry ties and thru-wall flashings.
If installed, soil pressures can cause the "dimples" in the drainage core to displace or damage the waterproofing membrane.
Waterstops are manufactured products available in a wide range of configurations and sizes. Based on some extensive excavation and waterproofing experience, it has been found that corrugated PVC drain tile piping can collapse under the weight of backfill, and the preference is to use stiffer PVC pipe if possible.


For surface moisture loadings such as rain and snow, the first line of control is the upper screen at the exterior surface. Backfilling with native, poor draining soil is not recommended as this will maintain an active water load on the foundation wall and limit its ability to control moisture ingress to the interior. In these cases the remaining part of the system is a dampproofing applied directly to the exterior surface of the foundation wall. However, since some municipalities charge for water pumping into storm drain systems, these costs must be weighed over the life of the structure when designing the waterproofing systems.
This finish is dependent on the interior use whether it be a controlled office environment or a non-controlled parking environment. In many cases the exterior facade element, whether it be brick, stone, etc., is carried down to just below grade level to properly transition and protect this sensitive area.
Distribution systems within the foundation walls themselves must be treated with careful consideration, as they can also be conduits transporting air and moisture within the structure. Proper design to connect downspouts into perimeter drain systems directly instead of flowing onto the area directly adjacent to the foundation wall is prudent in design. Sheet products are advantageous in terms of consistency in product material properties and thickness, but the primary drawback is the numerous laps that are required. One potential disadvantage is the inability of some liquid products to span cracks or opening of construction joints, which may occur on new buildings soon after application.
Methods for concrete placement include cast-in-place between the lagging and interior forms, or spray applied shotcrete. Prefabricated synthetic drainage layers are sometimes used in lieu of protection board for protecting waterproofing membranes.
The slip plane can reduce stresses imposed on the membrane during controlled backfill operations; these stresses can cause membrane damage, wrinkling, loss of adhesion, or delamination.
There is a combination of environmental design loadings at this interface such as surface water, runoff, and cavity wall drainage.
Limiting the direct contact of moisture with the isolation or flashing detail at the envelope seal is a very effective practice.
Sewer pipe penetrations, water line entry penetrations, drain basins in the floor slab or sleeves for electrical, gas or communication are all common penetrations, typically with their own design or detailed features. Sealing these generally requires application of elastomeric boots that seal to the housing and to the exterior pipe. For treatment of leaks providing amplified external drainage media similar to that required on the exterior wall is highly effective. A liquid membrane cant covered with an elastomeric flashing extending to the edge of the footer and several inches above the cant has proven historically effective. The actual design and configuration will vary based on applicable local, state, and national building code requirements, climate considerations, and economic constraints unique to each project.
This is calculated based on the information you provide us with the added load or loads anticipated. These breakers require a full space in a sub-panel and if your existing sub-panels utilizes, twin or wafer circuit breakers, than chances are you don’t have enough space and a bigger sub-panel will need to be installed.
I may have to re-roof - Has modern technology suggested a new method to vent a Big Beam home? From talking to 4 insulation contractors, one main problem is the tight space, only 4 inches, between the slanted ceilings in the 2nd floor closets that flank our staircase and the roof sheathing. 71-78, Association for Preservation Technology International (APT), available online at JSTOR. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order.
It is intended to provide a "Best Practice" and shall not be construed in any manner to establish the legal standard of care required from licensed professionals. For most portions of the foundation wall, water removal and control is of prime importance.
The fabrics are available in various forms including non-woven for clay type soils and woven or small opening geotextiles for sandy or high-silt type soils. Although marketed to be used with excavated soils during backfill in lieu of a granular drainage layer, it is recommended that a full system approach be used in applications where water leakage is not tolerable; a full system approach should include both a synthetic drainage layer and granular drainage layer. Woven products are constructed using individual threads or filaments and have good strength and stiffness; however, the material can be penetrated by angular aggregate reducing the ability to properly filter or separate fine elements.
Blind-side waterproofing systems are pre-applied to the area where the concrete element will be placed that is directly exposed to moisture. It is always better to have a continuously bonded and adhered waterproofing layer to reduce the potential for lateral moisture migration beneath the membrane. Bentonite is, therefore, most effective when properly confined so the product can swell to fill voids and so that it cannot be washed away.
Where grade slopes down along an exterior wall, the waterproofing will step down incrementally so that it continues to protect the below grade, occupied space.
Additionally, the composite cores have sharp corners that can cut the waterproofing membrane during installation or backfill operations.
Common materials include polyvinyl chloride (PVC), neoprene, expanding sodium bentonite and thermoplastic rubber. Typical hydrostatic and soil pressures generally range from 30 to 62.4 psf per foot of depth.
This upper screen may consist of relatively permeable landscape areas ranging to impermeable pavers, concrete or asphalt surfaces that will shed the majority of surface moisture.
As moisture moves from the upper screen through the drainage system on the exterior towards the exit drain, moisture will inevitably make its way toward the surface of the foundation wall itself. Building codes also generally require waterproofing if the ground-water level cannot be maintained at least 6 in. Portions of the building permanently below the water table may require more redundant systems. However, the use and location of the insulation is more important on the control of moisture in terms of preventing condensation on interior wall faces for the entire height of the foundation wall. Laps should be installed so that the upper sheet is lapped over the lower sheet so that water is shed naturally across the lap.
With bentonite systems, lapping of bentonite sheets is typically backlapped from the exterior if concrete placement involves pouring from the top of the wall. Caution is advised with use over softer liquid applied materials as the drainage layer may dig into and breach the membrane. Extruded polystyrene insulation boards should be properly supported on the footing to prevent vertical movement. These features, however, leave much to be desired with respect to sealing and waterproofing.
Other surfaces such as gas pipes, signal or electrical should generally be done with due consideration for the nature of the sleeve through the exterior wall and the depth below grade of the penetration.
Special emphasis is placed on evacuating the water at the wall base to avoid water build-up in the back fill or drainage system. Where the foundation wall is required to be waterproofed, adding a waterstop to the construction joint is recommended.
Full compliance with manufacturers' recommendations and recognized industry standards is recommended, and should be reflected in the appropriate sections of the project specifications. When possible, we will supply you with additional amperage and breaker space beyond your added load requirements, for future.
I have ridge vent and last year added more sofit vents so that I have a 12 inch vent every third rafter.
3 of the 4 contractors really don't want to deal with my problem, said they would get back to me, and never did. A In 1993, the Council became part of the School of Architecture, and since then has been known as the School of Architecture-Building Research Council.
Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home.
However, water removal measures around foundation walls below the water table may be impractical and expensive over the long-term and the waterproofing strategy becomes critical.
Many drainage mats also include a polyethylene sheet backer to uniformly disperse the loads imposed on the membrane and reduce the potential for damage caused by non-uniform profiles (dimples) in the composite core. Non-woven products are typically continuously extruded and spun and then needle-punched to create uniform openings that can be selected depending on the design. Understanding the specific chemical admixture is important in determining its potential performance in below-grade dampproofing or waterproofing applications. Even these systems should only be considered for use as a secondary (back-up) waterproofing to a positive-side waterproofing system, unless they are used with special details provided by a waterproofing expert which are beyond the scope of what are usually provided by system manufacturers. Therefore, a protection layer is recommended between the waterproofing membrane and the drainage layer.
Surcharge loadings may include live loads from pedestrian walkways or from vehicular roadways. The effectiveness of this initial screen in shedding moisture may influence the design of the other components of the system. Depending on the quantity of water that makes its way through the upper screen, a drainage system at the surface of the foundation wall is generally required to direct this water expeditiously toward the base of the foundation wall and the exit drain. For example, crystalline waterproofing is often used to provide redundancy to one of the other waterproofing systems. Condensation is possible in below grade conditions in warmer more humid summer conditions as below grade spaces tend to be cooler in the summer because of the insulating effect of the backfill soil. In many applications the interior finish is simply the interior surface of the material used for the foundation wall, i.e.
Where sheet materials are utilized, it is preferred to adhere the membrane fully and continuously to the substrate to prevent lateral migration of leaks, and to heat-weld or positively bond the seam laps.
Bentonite sheets are also typically shingle lapped with the lateral direction of the concrete placement.
With these softer waterproofing membranes protection board is recommended under the synthetic drainage layer or drainage layers with integral polyethylene backing may also be appropriate.
In addition, mechanical attachment of insulation or other materials that would penetrate or place stress on the membrane should be avoided.
Penetrations can also become quite exotic such as steam penetrations or other features that require special treatment. Will spraying the sides of the rafter and adding some rigid board insulation between the rafter and sheeting work? Someone told us we needed to insulate the system and replace some of the tiles with plastic egg grates. Carson Dunlop Associates' provides extensive home inspection education and report writing material. In the upper areas of the foundation wall thermal loading considerations must be addressed.
In general, when properly designed, non-woven products have good filtration and separation properties. Areas designed as pedestrian areas should also include consideration for emergency vehicular loadings. Some municipalities also limit pumping of groundwater as this can lower groundwater levels and affect the support of adjacent structures. This cooling effect combined with general poor air circulation in underground spaces can result in condensation on interior wall surfaces. When using cast-in place concrete, detailing of the form ties is critical and using single sided forms braced back to the slab can minimize this detailing. If adhesives are used to attach an element to the membrane, the adhesive pattern should be installed in small dabs to allow vertical water discharge and reduce the potential for hydrostatic pressures imposed on the waterproofing membrane.
Because of the unique nature of penetrations and Special Features, no single rule or criteria can govern or apply to the effective treatment thereof.
Considering two options; (i) foaming all of the HVAC ducts , better sealing all of the can lights and vents, then putting 4 inches of additional fiberglass (blown in) or extending the vent chutes to the ridge - in each rafter and spraying foam to the underside of the deck-removing the R-48 from the ceiling rafters.
His recommendation: blow in cellulose from the top down into this 4 inch wide space and then go into the closets and blow cellulose through the interior walls between each stud making a top and bottom hole. The Council's researchers answered many critical questions that would affect the quality of the nation's housing stock.How could homes be designed and built more efficiently? Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Blind-side systems are typically either a waterproofing sheet or an impermeable clay-based material. In areas with greater moisture loads from hydrostatic pressure from high water tables or sensitive interior environments, a waterproofing membrane should be applied to the exterior surface of the foundation wall in lieu of dampproofing.
Detailing around shoring piles and soil tie-back anchors can be challenging and reducing the number or frequency of these types of penetrations will increase the potential for good performance of the waterproofing system. However, classification of common penetration types and features helps to ensure effective treatment and proper function.
I just looked up R values and 4 inches of cellulose is only about 10; probably not good enough to prevent all future ice dams. Waterproofing membranes are predominantly applied to the positive (exterior) face of the foundation wall, however, there are negative-side waterproofing systems that can be applied to the interior of the foundation wall, and blind-side waterproofing systems that can be pre-applied to a support-of-excavation wall resulting in a waterproofing system installed on the positive side.
Diligent inspection and repair of the waterproofing after reinforcing steel is placed is a critical step, as steel placement often results in damage to the waterproofing that can not be repaired once concrete is placed. In these cases, the concrete foundation wall is placed against the blind side waterproofing membrane. Shotcreting can result in undesirable conditions such as voids behind reinforcing steel, and as a result some waterproofing manufacturers do not recommend their products for this application. I called a general contractor and he said that I don't want to give up that flow of cold air from sofit vents to ridge vents by filling that space with insulation. In combination with bentonite sheet waterproofing, these voids can be detrimental, since the bentonite can swell into the voids and loose its waterproofing integrity. Bottom line: if i go with this insulation contractor I will get some insulation but will eliminate the winter cold air ventilation that is also nice to have under the roof sheathing. Careful attention to installation is critical during both cast-in-place and shotcrete applications in blind-side waterproofing assemblies. He said that he found gaps around the chimney, around lights and around ceiling fans) Your comments are appreciated, thank you.



Free 12x16 wood shed plans online
How to build a 10x10 metal shed instructions
Shed style homes nz
Author: admin | 02.08.2015 | Category: Firewood Shed Plans


Comments »

  1. JIN — 02.08.2015 at 23:17:36 Each one might be a person storage difference in how.
  2. Ayka18 — 02.08.2015 at 19:57:36 Weaving among the wood putting up metallic sheds is slightly like height of a DVD storage.
  3. ayka012 — 02.08.2015 at 16:14:30 Your shed with home windows, doors christmas.