The thermal performance of the FPMR12TR7503*A is best-in-class: Little derating is needed up to 85, under natural convection. Electrical Engineering Stack Exchange is a question and answer site for electronics and electrical engineering professionals, students, and enthusiasts. There's no such thing as "lossless" anything in electronics, and there's not a single IC that's designed to do what you want. R1 essentially drops the difference between the Zener diode and the AC mains potential, so it's not going to be efficient for anything except light loads. This introduces a bulky, costly transformer into the design, but it's more efficient than the previous design, and your load can vary quite a bit. As you can see, AC mains voltage is immediately rectified and filtered to produce high voltage DC. These converters, in general, provide a great amount of efficiency and can also source high-power loads. The 7805 in figure 4 immediately reduces efficiency to under 70% due to very high dropout voltage of regulator. These circuits are so far good enough (taken from the Internet): less components + isolation bonus. I am mildly surprised that while the Non-Isolating Zener Supply was provided, there is no mention of a non-isolating capacitive reactance circuit voltage divider. If the device functions within a narrow current requirement, this can be reasonably efficient. IMO, a MOV (metal-oxide varistor) should be added to all of these designs to protect against line transients. It's very nice to have no external components required (or, at least very few compared to the typical support for a switched mode DC-DC converter IC). This circuit replaced all 1N4001 rectifiers with 1N5819 Schottky rectifiers and used a low dropout linear regulator AMS1117-5.0.
An LDO with PMOS pass element (AMS1117 used PNP BJT) can have even smaller loss (headroom of a few tens of millivolts from its \$R_{ds(on)}\$) and hence more efficient.
Not the answer you're looking for?Browse other questions tagged voltage ac dc converter or ask your own question. Is there an adjective for "untruthful, especially when pretending to know more than one actually does"?
SUNYAUN DC-DC Converter can operate well in any conventional circuits without any external components. One of the main features of SUNYUAN DC-DC Converter is that the high galvanic isolation, so user can only uses single DC-DC Converter to form various kinds of electric potential difference.
The table below lists the recommended values for the inductor and the capacitor in forming the waver filter.
Using the series connection of inductance can prevent generating over-current when connecting the power supply.
If the thermal resistors or other heat sensitive devices are close to the electric resistance, the over-load case can be detected.
Note: All the SUNYUAN power modules have the minimum load requirements, generally more than 10%, which can largely improve the reliability of the system.


In parallel connection, the same model of DC-DC Converters should be used to get better performance. In parallel connection of DC-DC Converter, users must pay attention that the switching action of every converter may not synchronous.
Another parallel connection is that connecting an inductor in the output terminal for each DC-DC Converter (see Fig 12 ). In parallel connection, the ripple wave value increase when more converters added, then user can add a filter capacitor in parallel connection output terminal to reduce ripple wave value. This method also applies to display window input terminal, and for the values for the filter inductor in parallel connection input terminal and filter capacitor in parallel connection, check the table above for reference. In conclusion, the parallel connection of DC-DC Converter is only used in some special situations. Also, your load can't change dramatically, as the resistor has to be sized to provide enough current to the zener to cause it to reverse avalanche, without providing too much current. These work on the principle of first converting AC to DC, then switching the DC at very high frequencies to make optimal use of the transformer's characteristics, as well as minimize the size (and loss) of the filter network on the secondary. The Power Integrations device switches this voltage rapidly across the transformer's primary side. These are the sorts of supplies you see in everything from tiny cell phone chargers to laptop and desktop computer power supplies.
You still have to give it some headroom to cover mains voltage variations, the diodes also mean a 30 % efficiency loss.
The proper using methods prolong the convertersa€™ service life and avoid the defects caused by interference, superheat, self-activation, abnormal activation,etc and other irreparable damage.
It realize the isolation between input and output, and provides one or more sets of isolated output power supply, or forms various voltage or polarity power supply circuits (see Fig. If necessary, output positive can be connected with input GND, then the negative of output terminal has a negative voltage.
And users be advised the current rated value of inductor should be about two times bigger than that the real current in usage.
But in normal operating conditions, output circuits have no protection functions for the over-current and short-circuit, so if there exists over-current or short-circuit conditions, the input terminal of DC-DC Converter will generate very heavy current to meet the requirements from the output terminal. The fuse here must have enough capacity to ensure that it will not be damaged by surge current when connecting the power supply (see Fig. But the temperature of the whole system should be considered to set proper switching rated values for different operating conditions (see Fig.
For the unregulated voltage converter, in the light load conditions, the output voltage will rise highly shortly or even in uncertain states, and for the regulated voltage products, the stability will decline when it is lower than the minimum load. Some matching methods are available: one is that adopts diode isolation which mainly used high voltage output conditions, such as 12V,15V.
Comparing this method with previous methods, this method consumpts less voltage, and a proper inductor is matched with a capacitor can reduce output ripple wave. Using a single high power consumption converter is better than that using DC-DC Converter group in parallel connection. I want to connect my microcontroller to an ordinary electrical socket and I don't have enough space available.


The input terminal and output terminal are isolated, so the connection modes of output terminal has no special requirements. This circuit configuration model is generally applied in measuring meters, data process and other noise sensitive circuits whicht require to isolate load and noise to avoid filtering or transmitting noise through power supply circuits and GND. If these conditions cannot be adjusted for a long time, the converter will be burnt because of over-heat.
The reason is that the output voltage for different models of converter is not completely the same, so it cannot ensure the real output power consumption of 2W converters is exactly the 2 times of that from 1W converter.
The table above lists the inductance values for different voltage values, and use these inductors can reduce ripple wave value in the circuit. For example: connecting two pieces of single voltage output DC-DC Converter in parallel, the filter capacitance value for the capacitor between the common positive and 0V should be 2uF. When connecting converters in parallel, the output voltage mismatch degree for every converter should have appropriate ratio. For example, add a single terminal connecting line, then new output emerged in the main power supply or divides into other different DC voltage. External connecting the wave filtering components, especially input and output wave filtering capacitors can reduce the noise and also the output response time will be longer.
Here presents some protection solutions of DC-DC Converter in the case of over-load in the output terminal.
Users are recommended to check the mismatching degree for every converter in full load to guarantee that the mismatching degree is within 1%-2%. This is because high-frequency AC requires much smaller components to filter than line-frequency AC. For response time and noise norm, which is more important, it depends on the users in designing the circuits. In parallel connection, even use the same model of DC-DC Converter, not every converter has the same load.
Usually using the DC-DC Converter group in parallel connection with 0.9 power consumption ratio, in that method it can ensure consumption safety warranty for each converter.
If requires very low ripple wave value, user can connect an inductor in series, the capacitance value of output filtering capacitor is not too big.
If there exists intelligent power management system in the input terminal, an electric resistance (to replace the inductor connected in series ) can be connected in series in input terminal to detect the voltage drop coming through, in that case, power management system can function well.
The similar circuit can also be used in output terminal to detect its output circuit, but if the power management system is in the input terminal, the detector should be isolated.
In most cases, three DC-DC Converter are connected in parallel, users should consider that each converter must have much power consumption allowable degree.
The temperature of the electric resistance in output terminal can indicate the over-load exist or not and prevent isolation defects of the system.